− | ''' | + | '''CANNY Lab''' — integrated software development environment for PLCs [[CANNY 7]]. |
− | == Purpose of integrated development environment | + | == Purpose of integrated development environment Canny Lab == |
− | IDE | + | IDE Canny Lab is a tool for application development using functional block diagram language - CFD. It is used to write, debug, and upload programs to the internal memory of programmable logic controllers [[CANNY 7]]. |
== Minimum system requirements for СannyLab operation == | == Minimum system requirements for СannyLab operation == | ||
Line 37: | Line 37: | ||
== The user interface == | == The user interface == | ||
− | :''Main artcle'': '''[[ | + | :''Main artcle'': '''[[CANNY Lab Main window]]''' |
CannyLab user interface consists of a single window - the main application window. | CannyLab user interface consists of a single window - the main application window. | ||
Line 57: | Line 57: | ||
Integrated Development Environment CannyLab supports three types of files: | Integrated Development Environment CannyLab supports three types of files: | ||
− | * «cfd» | + | * «cfd» functional diagram files; |
* «ccx» system software files; | * «ccx» system software files; | ||
* «exe» standalone executable files for autonomous software upload to the controller without using CannyLab. | * «exe» standalone executable files for autonomous software upload to the controller without using CannyLab. | ||
− | + | Functional diagram files and standalone executable files for software upload to the controller, can be created in the CannyLab environment. System software files are supplied by the controller manufacturer and can be uploaded directly to the controller from the CannyLab application or used during creation of a standalone executable file. | |
− | === Creating a new | + | === Creating a new functional diagram file === |
− | Create a new | + | Create a new functional diagram file by selecting "File" → "New" in the main menu, with the hotkey «Ctrl+N», or by clicking [[File:4_5_1_1.png]] on the toolbar. |
− | The symbol "*" appears at the end of the file name in the header of the main window if any changes were made to the currently open file. If there were any changes made to the file, the user will be prompted to save it upon exiting the editor or creating a new | + | The symbol "*" appears at the end of the file name in the header of the main window if any changes were made to the currently open file. If there were any changes made to the file, the user will be prompted to save it upon exiting the editor or creating a new functional diagram. |
− | === Saving the | + | === Saving the functional diagram file === |
− | Save the | + | Save the functional diagram file under a new name by selecting "File" → "Save as..." in the main menu, in this case the name of the saved file and the path to it is set in the pop-up dialog box. |
Save the file under the same name by selecting "File" → "Save" in the main menu, using the hotkey «Ctrl+S» or by clicking [[File:4_5_2_1.png]] on the toolbar. | Save the file under the same name by selecting "File" → "Save" in the main menu, using the hotkey «Ctrl+S» or by clicking [[File:4_5_2_1.png]] on the toolbar. | ||
Line 77: | Line 77: | ||
If the diagram being saved would overwrite a file created in an earlier CannyLab version, the user is presented with a warning stating that the file won’t be able to be opened in older versions of CannyLab. | If the diagram being saved would overwrite a file created in an earlier CannyLab version, the user is presented with a warning stating that the file won’t be able to be opened in older versions of CannyLab. | ||
− | === Opening of the | + | === Opening of the functional diagram file === |
Open an existing function diagram file, by selecting "File" → "Open..." in the main menu, using the hotkey «Ctrl+O» or by clicking [[File:4_5_3_1.png]] on the toolbar. | Open an existing function diagram file, by selecting "File" → "Open..." in the main menu, using the hotkey «Ctrl+O» or by clicking [[File:4_5_3_1.png]] on the toolbar. | ||
Line 85: | Line 85: | ||
The user is presented with a warning when they open a file created in an earlier version of CannyLab. An additional warning will appear if the current version of CannyLab can not correctly display all the information contained in the legacy file format. | The user is presented with a warning when they open a file created in an earlier version of CannyLab. An additional warning will appear if the current version of CannyLab can not correctly display all the information contained in the legacy file format. | ||
− | == | + | == Functional Diagram Editor == |
− | :''Main article'': '''[[ | + | :''Main article'': '''[[CANNY Lab Functional Diagram Editor]]''' |
− | The | + | The functional diagram editor is the main method of working within CannyLab. In the functional diagram editor mode, the user can: |
* add function blocks to the diagram; | * add function blocks to the diagram; | ||
* move function blocks within the diagram; | * move function blocks within the diagram; | ||
* select and delete diagram elements; | * select and delete diagram elements; | ||
− | * add connections between the | + | * add connections between the functional blocks to the diagram. These are called networks; |
* add and edit the names of networks on the diagram; | * add and edit the names of networks on the diagram; | ||
* merge, split and change the configuration of networks; | * merge, split and change the configuration of networks; | ||
− | * change the numbering of | + | * change the numbering of functional blocks; |
* assign input data sources and output data recipients of function blocks by using constants and controller resource registers. | * assign input data sources and output data recipients of function blocks by using constants and controller resource registers. | ||
− | == | + | == CANNY Lab Simulator == |
− | :''Main Article'': '''[[ | + | :''Main Article'': '''[[CANNY Lab Simulator]]''' |
− | Working in the simulator mode, CannyLab performs actions to diagram data that are equivalent to | + | Working in the simulator mode, CannyLab performs actions to diagram data that are equivalent to ones that would be carried out on them by a computing controller kernel, which allows the user to simulate the operation of the controller on the PC. |
− | The user has the ability to simulate the execution of the | + | The user has the ability to simulate the execution of the functional diagram for debugging and testing at any stage of its development. In the simulator mode, it is possible to run the diagram on a per-cycle and per-step basis, set the conditions for suspension of execution, forcibly set the input and output values of the function blocks, control intermediate values. |
{| | {| | ||
Line 117: | Line 117: | ||
:''Main article'': '''[[Interaction with equipment]]''' | :''Main article'': '''[[Interaction with equipment]]''' | ||
− | IDE CannyLab allows the user to upload system software to the controller. System software is required for execution of the | + | IDE CannyLab allows the user to upload system software to the controller. System software is required for execution of the functional diagram, as well as the overall operation of the functional diagram itself. |
== Executable files for autonomously uploading software into the controller == | == Executable files for autonomously uploading software into the controller == | ||
Line 125: | Line 125: | ||
IDE CannyLab allows users to create a custom standalone executable EXE-file containing controller system software and a function diagram. | IDE CannyLab allows users to create a custom standalone executable EXE-file containing controller system software and a function diagram. | ||
− | The purpose of this file is quick and easy controller configuration in a way comprehensible to the end user, as well as upload of software to the controller without relying on CannyLab IDE. From now on, we will refer to such files as automatic utilities for uploading software to the controller or SFX-files. | + | The purpose of this file is quick and easy controller configuration in a way comprehensible to the end user, as well as upload of software to the controller without relying on CannyLab IDE. From now on, we will refer to such files as automatic utilities for uploading software to the controller or SFX-files (SFX standing for self-extracting). |
Revision as of 09:40, 10 December 2020
CANNY Lab — integrated software development environment for PLCs CANNY 7.
Contents
- 1 Purpose of integrated development environment Canny Lab
- 2 Minimum system requirements for СannyLab operation
- 3 Installing and program launch
- 4 The user interface
- 5 Working with Files
- 6 Functional Diagram Editor
- 7 CANNY Lab Simulator
- 8 Interaction with the controller
- 9 Executable files for autonomously uploading software into the controller
Purpose of integrated development environment Canny Lab
IDE Canny Lab is a tool for application development using functional block diagram language - CFD. It is used to write, debug, and upload programs to the internal memory of programmable logic controllers CANNY 7.
Minimum system requirements for СannyLab operation
CPU type, CPU clock speed: | Intel ® Pentium ® 233MHz or higher. |
OS: | Windows ® 2000, Windows XP ™, or higher. |
RAM size: | 128 MB (256 MB recommended). |
Video adapter and monitor: | SVGA or higher resolution monitor (1024x768 recommended). |
Free disk space: | 110 MB (150 МB recommended). |
Input Devices: | Keyboard, mouse. |
USB: | 1.1 or higher. |
Installing and program launch
Integrated Development Environment CannyLab is distributed as a "portable" version. It does not require installation and can be run from removable media. Download the program archive from the website http://www.cannylogic.com/c7 and unzip it to a folder on your PC or an external drive. Run the file cannylab.exe from the program folder. It is not recommended to run multiple program instances.
The user interface
- Main artcle: CANNY Lab Main window
CannyLab user interface consists of a single window - the main application window.
The main window is divided into several areas:
- window title;
- main menu;
- toolbar;
- function block panel;
- workspace;
- status bar.
Depending on the current operating mode of the editor, some of CannyLab menu items and panels may not be available or hidden.
Working with Files
Integrated Development Environment CannyLab supports three types of files:
- «cfd» functional diagram files;
- «ccx» system software files;
- «exe» standalone executable files for autonomous software upload to the controller without using CannyLab.
Functional diagram files and standalone executable files for software upload to the controller, can be created in the CannyLab environment. System software files are supplied by the controller manufacturer and can be uploaded directly to the controller from the CannyLab application or used during creation of a standalone executable file.
Creating a new functional diagram file
Create a new functional diagram file by selecting "File" → "New" in the main menu, with the hotkey «Ctrl+N», or by clicking on the toolbar.
The symbol "*" appears at the end of the file name in the header of the main window if any changes were made to the currently open file. If there were any changes made to the file, the user will be prompted to save it upon exiting the editor or creating a new functional diagram.
Saving the functional diagram file
Save the functional diagram file under a new name by selecting "File" → "Save as..." in the main menu, in this case the name of the saved file and the path to it is set in the pop-up dialog box.
Save the file under the same name by selecting "File" → "Save" in the main menu, using the hotkey «Ctrl+S» or by clicking on the toolbar.
If the diagram being saved would overwrite a file created in an earlier CannyLab version, the user is presented with a warning stating that the file won’t be able to be opened in older versions of CannyLab.
Opening of the functional diagram file
Open an existing function diagram file, by selecting "File" → "Open..." in the main menu, using the hotkey «Ctrl+O» or by clicking on the toolbar.
Alternatively, the diagram file can be opened by dragging it into the CannyLab open window.
The user is presented with a warning when they open a file created in an earlier version of CannyLab. An additional warning will appear if the current version of CannyLab can not correctly display all the information contained in the legacy file format.
Functional Diagram Editor
- Main article: CANNY Lab Functional Diagram Editor
The functional diagram editor is the main method of working within CannyLab. In the functional diagram editor mode, the user can:
- add function blocks to the diagram;
- move function blocks within the diagram;
- select and delete diagram elements;
- add connections between the functional blocks to the diagram. These are called networks;
- add and edit the names of networks on the diagram;
- merge, split and change the configuration of networks;
- change the numbering of functional blocks;
- assign input data sources and output data recipients of function blocks by using constants and controller resource registers.
CANNY Lab Simulator
- Main Article: CANNY Lab Simulator
Working in the simulator mode, CannyLab performs actions to diagram data that are equivalent to ones that would be carried out on them by a computing controller kernel, which allows the user to simulate the operation of the controller on the PC.
The user has the ability to simulate the execution of the functional diagram for debugging and testing at any stage of its development. In the simulator mode, it is possible to run the diagram on a per-cycle and per-step basis, set the conditions for suspension of execution, forcibly set the input and output values of the function blocks, control intermediate values.
Note: | Current CannyLab simulator version is not supporting controller hardware resources, so the reading results of addresses and write to the address in the simulator may differ from the results obtained during diagram execution by the controller. |
Interaction with the controller
- Main article: Interaction with equipment
IDE CannyLab allows the user to upload system software to the controller. System software is required for execution of the functional diagram, as well as the overall operation of the functional diagram itself.
Executable files for autonomously uploading software into the controller
- Main article: Firmware Update Utility
IDE CannyLab allows users to create a custom standalone executable EXE-file containing controller system software and a function diagram.
The purpose of this file is quick and easy controller configuration in a way comprehensible to the end user, as well as upload of software to the controller without relying on CannyLab IDE. From now on, we will refer to such files as automatic utilities for uploading software to the controller or SFX-files (SFX standing for self-extracting).