General description
CANNY 7 supports high-resolution pulse-width modulator mode for two of twelve IO channels (Channels #1 and #2). This channels may be activated independently of each other and have independent duty cycle and pull-up line configuration, however, the high resolution PWM period is a parameter common to both channels. In HR PWM mode, PWM timing - the period and duty cycle are set in the range from 2 to 20,000 microseconds, in increments of 1 microsecond.
In HR PWM, the channel has a fixed pulse polarity - GND 100mA. Generation can be conducted in either open collector (no pull-up lines or external pull-up) or with internal pull-up to +12V (specified by setting the value in the appropriate register). In this mode, the channel is asynchronous to functional diagram, which allows for maximum timing stability of generated signal.
The driver of high resolution pulse width modulator (HR PWM) operates using Discrete Inputs and Outputs resources, wherein, having a higher priority. Thus, upon activation of the HR PWM driver, controllers channels used by it are unavailable to input-output drivers.
Note:
|
In high resolution pulse width modulator mode, the electrical protection from short circuit is disabled! Overload or channel short-circuit which are in high resolution PWM mode, can lead to controller failure!
|
Drivers Registers
The following shows permissible values for control registers of high resolution PWM driver.
Address
|
Expected Values
|
HR PWM 1 & 2 Period Register, μs
|
1...20000
|
=
|
specify the period in microseconds RR PWM generator for both channels. The value in excess of 20,000 will be accepted as 20,000.
|
|
HR PWM 1 Enable Register
|
HR PWM 2 Enable Register
|
|
1...65535
|
=
|
transfer controller channel in to high resolution pulse width modulator mode;
|
0
|
=
|
return controller channel to normal mode.
|
|
HR PWM 1 Duty Register, μs
|
HR PWM 2 Duty Register, μs
|
|
1...20000
|
=
|
set HR PWM channel filling (duty cycle) in microseconds. The value in excess of 20,000 will be accepted as 20,000.
|
|
HR PWM 1 Pull-up Enable Register
|
HR PWM 2 Pull-up Enable Register
|
|
|
An example of a functional diagram, continuously adjustable HR PWM duty cycle with carrier frequency 10 kHz on channel #1, by pressing / holding the buttons connected to the channels #9 and #10:
See also
CANNY 7
CANNY 7, Discrete IO Driver